STABILITY FACTORS IN GAS METER VERIFICATION LABORATORIES: MATHEMATICAL MODELING AND ERROR CONTRIBUTION ASSESSMENT
Keywords:
gas meter, verification facility, instability, flow pulsation, measurement error, compressibility factor, Monte Carlo simulation.Abstract
Instability in verification facilities used for gas meter calibration arises from multiple physical and metrological factors, including pressure and temperature fluctuations, flow pulsations, gas compressibility and composition changes, hydraulic regime variations in pipelines, sensor drift, regulator dynamics, and reference channel uncertainties.
References
Idelchik, I. E. Aerodynamics of Technological Apparatus. Moscow: Mashinostroenie Publishers, 1983, 351 p.
Ginevskiy, A. S., Vlasov, E. V., Karavosov, R. K. Acoustic Control of Turbulent Jets. Moscow: FIZMATLIT, 2001, 240 p. ISBN 5-9221-0161-7.
Mikheev, N. I., Molochnikov, V. M., Davletshin, I. A., et al. Hydrodynamic and heat transfer processes in pulsating flow. In: Proceedings of the VI School-Seminar on Problems of Heat and Mass Transfer and Hydrodynamics in Power Engineering. Kazan, 2008, pp. 48–76.
Gündogdu, M. Y., Carpinlioglu, M. O. Present State of the Art on Pulsatile Flow Theory (Part 1: Laminar and Transitional Flow Regimes). Journal of the Japan Society of Mechanical Engineers, Series B, 1999, Vol. 42, No. 3, pp. 384–397.
Gündogdu, M. Y., Carpinlioglu, M. O. Present State of the Art on Pulsatile Flow Theory (Part 2: Laminar and Transitional Flow Regimes). Journal of the Japan Society of Mechanical Engineers, Series B, 1999, Vol. 42, No. 3, pp. 398–410.
Alemasov, V. E., Glebov, G. A., Kozlov, A. P. Thermoanemometric Methods for Studying Separated Flows. Kazan: Kazan Branch of the USSR Academy of Sciences, 1989, 178 p.